    Zeitronix Black Box Data Logger for Zt-2 and Zt-3 Wideband Systems

    PART#
    We Price Match!

    Contact us to ensure you're getting the right part for your car at the absolute best pricing on earth!

    Email - sales@maperformance.com
    Phone 1(888)627-3736



    $ 109.00



    This item is built to order
    and typically ships in 3-5 Days!

    If ordered within hours and minutes
    This item can be delivered by ,
    Fits Your
    MAP Loyalty: Earn $ 2.18 Toward Next Purchase!

    The Zeitronix Black Box Data Logger is a flash memory data logger for use with Zeitronix Zt-2 or Zt-3 Wideband systems. The logger accepts 1GB or 2GB Micro SD flash memory cards. Power and data are supplied through a single 5 ft (1.5m) cable plugging directly into the Zt-2 or Zt-3 DATA port.

    Features

    • Large button for easy activation when wearing driving/racing/motorcycle/ATV gloves
    • LED activity indicator
    • Long 5 ft (1.5m) cable for accessing remote Zt-2 or Zt-3 Wideband controllers
    • Plug and play installation, no wiring required
    • Supports 1 GB or 2 GB Micro SD cards for 100's of hours of logging
    • Auto-saving keeps data in the event of a power loss

     

    INSTALLATION

    The Micro SD card must be formatted with a “FAT” (FAT16) file system. Plug the Zeitronix Black Box Data Logger connector into the Zt-2 or Zt-3 DATA port. A data splitter may be used if connecting alongside one or more Zeitronix displays such as the ZR-2 Multi-Gauge, ZR-1 AFR/Lambda Gauge, or LCD screen.

    Micro SD cards are inserted into the Zeitronix Black Box Data Logger face up, as shown to the right. The Micro SD connector slot is spring loaded. Push to insert and the card will lock in. Push again to remove and card will spring outward. 
    Inserting the Micro SD card upside down or backwards may result in connector damage.

    OPERATION

    Press the center of the button to start and stop logging sessions. The Zeitronix Black Box Data Logger will display a steady LED light when initially powered. Press the button one time to begin logging. The LED will flash quickly while logging data. Press the button again to end the log and the LED will become a steady light. The Micro SD card will now contain a file with the name "log001.sdl". Pressing the button again will begin a new log with the name "log002.sdl".

    Increasing values are used for each new log file name. A total of 255 logs can be created. Log file names will use the highest number available on the SD card until "log255.sdl" is reached. Logs will then be created using the lowest log file number available. If no file names are available the LED will blink two times to indicate an error.

    Files can be accessed by removing the micro SD card from the Black Box Data Logger. A micro SD card reader can be used to copy files from the card. The files have fixed created and accessed dates, for best results you may wish to copy the logs into a folder (directory) with a date matching when the logs were generated. Files are viewed with the Zeitronix Data Logger program available at:
    http://www.zeitronix.com/zdl/

    The Black Box Data Logger has no internal battery or parts which require maintenance. The Zeitronix Black Box Data Logger LED will repeat a single or double blink if an error has occurred, see the following table for details.

    Warnings

    For automotive use only. This product is for off road use only.
    This product is not water proof. To be used with Zeitronix Zt-2 or Zt-3 Wideband AFR Meter only.
    Never place in a location, which obstructs the view. Never tune the car while driving. 
    Tune responsibly. Zeitronix Inc. is not responsible for any damages.

     

    The Zeitronix Black Box Data Logger is a flash memory data logger for use with Zeitronix Zt-2 or Zt-3 Wideband systems. The logger accepts 1GB or 2GB Micro SD flash memory cards. Power and data are supplied through a single 5 ft (1.5m) cable plugging directly into the Zt-2 or Zt-3 DATA port.

    Features

    • Large button for easy activation when wearing driving/racing/motorcycle/ATV gloves
    • LED activity indicator
    • Long 5 ft (1.5m) cable for accessing remote Zt-2 or Zt-3 Wideband controllers
    • Plug and play installation, no wiring required
    • Supports 1 GB or 2 GB Micro SD cards for 100's of hours of logging
    • Auto-saving keeps data in the event of a power loss

     

    INSTALLATION

    The Micro SD card must be formatted with a “FAT” (FAT16) file system. Plug the Zeitronix Black Box Data Logger connector into the Zt-2 or Zt-3 DATA port. A data splitter may be used if connecting alongside one or more Zeitronix displays such as the ZR-2 Multi-Gauge, ZR-1 AFR/Lambda Gauge, or LCD screen.

    Micro SD cards are inserted into the Zeitronix Black Box Data Logger face up, as shown to the right. The Micro SD connector slot is spring loaded. Push to insert and the card will lock in. Push again to remove and card will spring outward. 
    Inserting the Micro SD card upside down or backwards may result in connector damage.

    OPERATION

    Press the center of the button to start and stop logging sessions. The Zeitronix Black Box Data Logger will display a steady LED light when initially powered. Press the button one time to begin logging. The LED will flash quickly while logging data. Press the button again to end the log and the LED will become a steady light. The Micro SD card will now contain a file with the name "log001.sdl". Pressing the button again will begin a new log with the name "log002.sdl".

    Increasing values are used for each new log file name. A total of 255 logs can be created. Log file names will use the highest number available on the SD card until "log255.sdl" is reached. Logs will then be created using the lowest log file number available. If no file names are available the LED will blink two times to indicate an error.

    Files can be accessed by removing the micro SD card from the Black Box Data Logger. A micro SD card reader can be used to copy files from the card. The files have fixed created and accessed dates, for best results you may wish to copy the logs into a folder (directory) with a date matching when the logs were generated. Files are viewed with the Zeitronix Data Logger program available at:
    http://www.zeitronix.com/zdl/

    The Black Box Data Logger has no internal battery or parts which require maintenance. The Zeitronix Black Box Data Logger LED will repeat a single or double blink if an error has occurred, see the following table for details.

    Warnings

    For automotive use only. This product is for off road use only.
    This product is not water proof. To be used with Zeitronix Zt-2 or Zt-3 Wideband AFR Meter only.
    Never place in a location, which obstructs the view. Never tune the car while driving. 
    Tune responsibly. Zeitronix Inc. is not responsible for any damages.

     

    Customer Reviews

    No reviews yet
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    MAP Limited Lifetime Warranty

    1.) All MAPerformance in-house fabricated parts include a Limited Lifetime Warranty for the Original Purchaser. This warranty only applies to the original purchaser and is non-transferrable. If the product fails it would need to be determined by MAPerformance that it is due to manufacturing defects in materials or workmanship.

    2.) This does not cover normal wear and tear. Improper use, modification, or abuse voids this warranty. MAPerformance will not be held responsible for additional costs due to the failure of a product (cost of sale, towing, labor, etc.). Warranty claims must be submitted to MAPerformance for review.

    3.) You must create a support ticket to acquire your return authorization number prior to returning the product.

    4.) Warranty claims will not be honored if the product was not purchased through an approved dealer.

    For warranty evaluation please create a support ticket via this form here.

    We use cookies to offer a better browsing experience, analyze site traffic, personalize content, and serve targeted advertisements. Please review our privacy policy & cookies information page.  If you continue you consent to our privacy policy & use of cookies.Accept

    Hello!

    Unfortunately due to vendor restrictions we are unable to sell this brand within Australia or the UK. If you have any questions, feel like you received this message in error or would like suggestions on other brands please contact us here.

    Hello!

    Unfortunately due to vendor restrictions we are unable to sell this brand within Australia. If you have any questions, feel like you received this message in error or would like suggestions on other brands please contact us here.

    Hello!

    Unfortunately due to vendor restrictions we are unable to sell this brand within your country. If you have any questions, feel like you received this message in error or would like suggestions on other brands please contact us here.

    Hello!

    Unfortunately due to vendor restrictions we are unable to sell this brand within California. If you have any questions, feel like you received this message in error or would like suggestions on other brands please contact us here.